My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD PREV. ORDINANCE 1996
Town-of-Mooresville
>
PUBLIC DOCUMENTS ON LINE
>
MINUTES
>
Plan Commission
>
1990-1999
>
1996
>
FLOOD PREV. ORDINANCE 1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2005 10:12:48 AM
Creation date
5/20/2005 11:50:37 AM
Metadata
Fields
Template:
Plan Commission
NAME
7-1996
Plan Commission - Type
Minutes
DATE
1996-10-24
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />elevation of the regulatory flood; and <br /> <br />2. For all projects involving channel modifications or filI (including levees) <br />the Town shall submit the data and request that the Federal Emergency <br />Management Agency revise the regulatory flood data. <br /> <br />b. Within all SFHAs identified as A Zones (no one hundred (100) year flood <br />elevation and/or floodwaylfIoodway fringe delineation has been provided) the <br />folIowing standard shall apply: <br /> <br />1. The total cumulative effect of the proposed development, when combined <br />with all other existing and anticipated development, will not increase the <br />regulatory flood elevation more than one-tenth (0.1) of one (1) foot and <br />will not increase flood damages or potential flood damages. <br /> <br />c. Public Health Standards in all SFHAs <br /> <br />1. No development in the SFHA shall include locating or storing chemicals, <br />explosives, buoyant materials, flammable liquids, polIutants or other <br />hazardous or toxic materials below the Flood Protection Grade, unless <br />such materials are stored in a floodproofed storage tank or building <br />constructed according to the requirements of Section VIII of this <br />Ordinance. <br /> <br />~ <br /> <br />2. New and replacement sanitary sewer lines and on-site waste disposal <br />systems may be permitted providing all manholes or other above ground <br />openings are located above the FPG or those which are located below the <br />FPG are watertight. <br /> <br />Section VIII. Protectin¡¡ Buildin¡¡s. <br /> <br />In addition to the damage prevention requirements of Section VII, all buildings to be <br />located in the SFHA shall be protected from flood damage below the FPG. <br /> <br />a. This building protection requirement applies to the folIowing situations: <br /> <br />1. Construction or placement of any new building having a floor area greater <br />than four hundred (400) square feet; <br /> <br />2. Structural alterations made to: <br /> <br />a. Any existing (previously unaltered) building, the cost of which <br />equals or exceeds fifty percent (505) of the value of the pre-altered <br />building (excluding the value of the land); <br /> <br />'--' <br /> <br />b. Any previously altered building; <br />
The URL can be used to link to this page
Your browser does not support the video tag.