My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ORDINANCES & RESOLUTIONS 1989
Town-of-Mooresville
>
PUBLIC DOCUMENTS ON LINE
>
ORDINANCES & RESOLUTIONS
>
1980-1989
>
1989
>
ORDINANCES & RESOLUTIONS 1989
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2005 10:11:47 AM
Creation date
5/9/2005 2:10:18 PM
Metadata
Fields
Template:
ZONING
YEAR
1989
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
108
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />I <br /> <br />(4) "Sleeping Area" shall be defined as the area of a unit <br />In which bedrooms or sleeping rooms are located. Bedrooms or <br /> <br />sleeping rooms separated by another use area such as a kitchen or <br /> <br />living room are separated sleeping areas, but bedrooms or sleeping <br /> <br />rooms separated by a bathroom are not separate sleeping areas. <br /> <br />SECTION II - SMOKE DETECTORS REQUIRED <br />All multiple family dwelling units and all mobile home <br />rentals shall be equipped with smoke detectors. <br />SECTION III - LOCATION <br />Smoke detectors shall be mounted on the ceiling or wall at a <br />point centrally located in the corridor or area giving access to <br />the rooms used for sleeping purposes. Where a common hallway lS <br /> <br />used, smoke detectors shall be spaced not more than twenty-five <br /> <br />feet apart in such hallway. All smoke detectors shall be located <br />either on the ceiling, not less than six inches from any wall, or <br /> <br />on a wall, not less than six nor more than twelve inches from the <br /> <br />ceiling, and within fifteen feet of all rooms used for sleeping <br />purposes, No detector shall be recessed into the ceiling. <br />SECTION IV - INSTALLATION <br />If a smoke detector is A.C. powered, it must be directly <br />attached to a junction box not controlled by any switch other than <br />the main power supply. The installation of A.C. powered detectors <br />shall conform to all electrical standards adopted by the City. A <br />smoke detector required under this ordinance shall be installed <br />according to the directions and specifications of the <br />manufacturer, but if in conflict with any city electrical <br />standard, the city electrical standard shall take precedence. <br />SECTION V - MAINTENANCE <br />It shall be unlawful for any person to tamper or remove any <br />smoke detector except when it is necessary for maintenance or <br /> <br />inspection purposes. Any smoke detector removed for repair or <br /> <br />replacement must be re-installed or replaced so that it is in <br /> <br />place during normal sleeping hours. At every change of tenant In <br /> <br />every multiple family dwelling unit or mobile home rental, smoke <br />detectors shall be tested to see that they are in operable <br /> <br />condition, <br /> <br />-2- <br />
The URL can be used to link to this page
Your browser does not support the video tag.