Laserfiche WebLink
<br />. <br />I <br />I <br />í <br />/. <br />I <br />I <br />, <br />i <br />, <br />I <br />I <br />I. <br />I <br />I <br />, <br /> <br />,¡ <br />,I <br />II <br />I <br /> <br />- <br /> <br />.' <br /> <br />,213. <br /> <br />Whenever possible, the building sewer shall be brought to the <br />building at an elevation below the basement floor. No building <br />sewer shall be laid parallel to or within three feet of any bearing <br />wall, which might thereby be weakened. The depth shall be suffi- <br />cient to afford protection from frost. The bUilding sewer shall be <br />laid at a uniform grade and in straight alignment insofar as possi- <br />ble. Changes in direction shall be made only with properly curved <br />pipes and fittings. <br /> <br />,It <br /> <br />214. <br /> <br />In all buildings in which any building drain is too low to permit <br />gravity flow to the public sewer, sanitary seWage carried by such <br />drsins shall be lifted b~ approved artificial means and discharged <br />to the building sewer. <br /> <br />21S. <br /> <br />All excavations required for the installation of a building sewer, <br />shall be open trench work, unless otherwise approved by the Inspec- <br />tor. Pipe laying and backfill shall be performed in accordance <br />with ASTM specifications applicable to the type of pipe being used, <br />except that no backfill shall be placed until the work has been <br />inspected by the Inspector or his representative. <br /> <br /> <br /> <br />216. All joints and connections shall be made gas tight and watertight, <br />and as governed by the Indiana Uniform Plumbing Code in effect as <br />of the date of adoption of this Ordinance, and any provisions <br />thereof which may be amendatory thereof' or supplemental thereto <br />from time to time hereafter. <br /> <br />216.1 Joints in vitrified clay pipe and f J.ttings shall be O-ring <br />type compression joint or the low profile type compression <br />joint utilizing a factory applied PVC collar or bell and a <br />factory applied resilient ,polyurethane compression seal on <br />the spigot end of the pipe. Joints shall meet or exceed all <br />requirements of ASTM Designation C-425, lstest revision. <br /> <br />. <br /> <br />216.2 Joints on PVC pipe and fittings shall be the integral bell <br />type and shall comply with all physical requirements of ASTM <br />Designations D-1869, C-361, and C-443, latest revision. <br /> <br />:'...,.. <br /> <br />, <br />, <br /> <br />216.3 Joints on ABS pipe and fittings shall be the solvent weld <br />type conforming to all requirements of ASTM Designation <br />D-2680, latest revision. <br /> <br />216.4 Joints on ductile iron and cast iron pipe shall be the push- <br />on type conforming to AWWA Designation C-151, latest revi- <br />sion. Fittings shall be ,cast iron and shall comply with <br />ANSI Specification A21.10, latest revision, with push-on or <br />mechanical joints. <br /> <br />l <br /> <br />216.5 Other jointing materials and methods may be used only upon <br />the approval of the Superintendent. <br /> <br />,217. The connection of the building sewer into the public sewer shall be <br />made at the Ny" branch or "Tee" connection, if such branch 1s <br />available at a suitable location. If the public sewer does not <br /> <br />-8- <br /> <br />.~ _._------~ ---.- <br />