My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
JAN. 23, 1992
Town-of-Mooresville
>
PUBLIC DOCUMENTS ON LINE
>
MINUTES
>
Plan Commission
>
1990-1999
>
1992
>
JAN. 23, 1992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2005 10:12:52 AM
Creation date
5/20/2005 11:50:37 AM
Metadata
Fields
Template:
Plan Commission
NAME
JAN. 23, 1992
Plan Commission - Type
Minutes
DATE
1992-01-23
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />165 Ibs/sq yd bituminous #11 surface on 440 lbs/sq yd bituminous base on <br />eight inches canpacted aggregate base; or <br /> <br />'- <br /> <br />110 lbs/sq yd #11 surface on 440 Ibs/sq yd of bituminous base on 440 lbs/sq <br />yd bituminous base. <br /> <br />Arterial and Industrial: <br /> <br />Ten inches reinforced Portland cement concrete on eight inches granular <br />("B" borrow) sub base; or <br /> <br />110 Ibs/sq yd of # 11 biruminous surface on 240 lbs/sq yd of bituminous base <br />on 440 Ibs/sq yd of bituminous base on 440 lbs/sq yd of bituminous base; <br />or <br /> <br />110 Ibs/sq yd #11 surface on 220 lbs/sq yd bituminous base on 440 Ibs/sq yd <br />bituminous base on eight inches canpacted aggregate base. <br /> <br />5. Prior to placing the street surfaces, adequate subsurface drainage for the street <br />shall be provided by the subdivider. Subsurface drainage pipe, when required, shall <br />be mated ccrrugated steel pipe or a similar approved type not less than 4 inches in <br />diameter approved by the Carmission. Upon the cœpletion of the street improvements, <br />plans and profiles as built shall be filed with the Carmission. <br /> <br />C. <br /> <br />Sewers <br /> <br />",- <br /> <br />The subdivider shall provide the subdivision with a canplete sanitary sewer <br />system, which shall connect with an existing approved sanitary sewer outlet, <br />except that when such approved outlet is not available, one of the following <br />methods of sewage disposal shall be used: <br /> <br />1. A cœplete sanitary sewer system to convey the sewage to a treatIœnt plant, <br />to be provided by the subdivider in accordance with the minimum <br />requirements of the Morgan County Health Department, the Indiana State <br />Board of Health, and/or the Indiana Stream Pollution Control Board. <br /> <br />2. A private sewage disposal system on individual lots as approved by the <br />Morgan County Health Deparbnent. <br /> <br />The plans for the installation of a sanitary sewer system shall be provided by the <br />subdivider and approved by the Indiana State Board of Health. The design shall give <br /> <br />'- <br /> <br />14 <br />
The URL can be used to link to this page
Your browser does not support the video tag.